EN 50288-7 Silicone Insulation OS Armoured Fire resistant
EN 50288-7 Silicone Insulation OS Armoured Fire resistant
- Instrumentation cables 170/300 V
- Overall Screen (OS)
- Oil resistant
EN 50288-7 Silicone OS Armoured 1x2x0,5
Nexans ref. 10135079
- Number of pairs: 1
- Conductor cross-section: 0.5 mm²
EN 50288-7 Silicone OS Armoured 2x2x0,5
Nexans ref. 10135080
- Number of pairs: 2
- Conductor cross-section: 0.5 mm²
EN 50288-7 Silicone OS Armoured 5x2x0,5
Nexans ref.
- Number of pairs: 5
- Conductor cross-section: 0.5 mm²
EN 50288-7 Silicone OS Armoured 10x2x0,5
Nexans ref.
- Number of pairs: 10
- Conductor cross-section: 0.5 mm²
EN 50288-7 Silicone OS Armoured 20x2x0,5
Nexans ref. 10135085
- Number of pairs: 20
- Conductor cross-section: 0.5 mm²
EN 50288-7 Silicone OS Armoured 30x2x0,5
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 0.5 mm²
EN 50288-7 Silicone OS Armoured 1x2x0,75
Nexans ref. 10135087
- Number of pairs: 1
- Conductor cross-section: 0.75 mm²
EN 50288-7 Silicone OS Armoured 2x2x0,75
Nexans ref. 10135088
- Number of pairs: 2
- Conductor cross-section: 0.75 mm²
EN 50288-7 Silicone OS Armoured 5x2x0,75
Nexans ref.
- Number of pairs: 5
- Conductor cross-section: 0.75 mm²
EN 50288-7 Silicone OS Armoured 10x2x0,75
Nexans ref.
- Number of pairs: 10
- Conductor cross-section: 0.75 mm²
EN 50288-7 Silicone OS Armoured 20x2x0,75
Nexans ref. 10135093
- Number of pairs: 20
- Conductor cross-section: 0.75 mm²
EN 50288-7 Silicone OS Armoured 30x2x0,75
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 0.75 mm²
EN 50288-7 Silicone OS Armoured 1x2x1
Nexans ref. 10135095
- Number of pairs: 1
- Conductor cross-section: 1 mm²
EN 50288-7 Silicone OS Armoured 2x2x1
Nexans ref. 10135096
- Number of pairs: 2
- Conductor cross-section: 1 mm²
EN 50288-7 Silicone OS Armoured 10x2x1
Nexans ref.
- Number of pairs: 10
- Conductor cross-section: 1 mm²
EN 50288-7 Silicone OS Armoured 20x2x1
Nexans ref. 10135101
- Number of pairs: 20
- Conductor cross-section: 1 mm²
EN 50288-7 Silicone OS Armoured 30x2x1
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 1 mm²
EN 50288-7 Silicone OS Armoured 1x2x1,5
Nexans ref. 10135103
- Number of pairs: 1
- Conductor cross-section: 1.5 mm²
EN 50288-7 Silicone OS Armoured 2x2x1,5
Nexans ref. 10135104
- Number of pairs: 2
- Conductor cross-section: 1.5 mm²
EN 50288-7 Silicone OS Armoured 5x2x1,5
Nexans ref.
- Number of pairs: 5
- Conductor cross-section: 1.5 mm²
EN 50288-7 Silicone OS Armoured 10x2x1,5
Nexans ref.
- Number of pairs: 10
- Conductor cross-section: 1.5 mm²
EN 50288-7 Silicone OS Armoured 20x2x1,5
Nexans ref. 10135109
- Number of pairs: 20
- Conductor cross-section: 1.5 mm²
EN 50288-7 Silicone OS Armoured 30x2x1,5
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 1.5 mm²
EN 50288-7 Silicone OS Armoured 1x2x2,5
Nexans ref.
- Number of pairs: 1
- Conductor cross-section: 2.5 mm²
EN 50288-7 Silicone OS Armoured 2x2x2,5
Nexans ref.
- Number of pairs: 2
- Conductor cross-section: 2.5 mm²
EN 50288-7 Silicone OS Armoured 5x2x2,5
Nexans ref.
- Number of pairs: 5
- Conductor cross-section: 2.5 mm²
EN 50288-7 Silicone OS Armoured 10x2x2,5
Nexans ref.
- Number of pairs: 10
- Conductor cross-section: 2.5 mm²
EN 50288-7 Silicone OS Armoured 20x2x2,5
Nexans ref.
- Number of pairs: 20
- Conductor cross-section: 2.5 mm²
EN 50288-7 Silicone OS Armoured 30x2x2,5
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 2.5 mm²
Description
Description
Standards
-
TestIEC 60331; IEC 60332-3-22 Cat.A
Applications
These instrumentation and communication cable are used to transmit analogue or digital signals in measurement and process control .They are well adapted to underground use in industrial application where chemical and mechanical protections are needed (refinery areas, chemical plant…). They maintain circuit integrity when exposed to fire.
Design
Conductor:
Stranded bare copper class 2
Insulation:
Silicone rubber (Sil)
Overall screen:
Polyester tape
Tinned copper drain wire
Aluminium backed polyester tape
Bedding (inner sheath):
Low Smoke Zero Halogen (LSZH)
Colour: black
Armour:
Galvanized steel wires (SWA)
Outer sheath:
Polyvinyl chloride (PVC)
Colour: black
Other colour on request.
Core identification
Pair: white - black
Quad: white - black - red - blue (2 pair cables assembled as a quad)
White core printed with pair number
Marking
NEXANS 279 SIL/OA.SCR/LSZH/SWA/PVC 170/300V Nber of pairs & cross-section Cu IEC 60331 IEC 60332-3-22(A) MM YYYY Manufacturing number + metric marking
Standards
EN 50288-7 (Design guide-lines)
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Selling & delivery Information
Other fire performances IEC 60332-1 or IEC 60332-3-24(C) and enhanced hydrocarbon resistance on request.
Minimum bending radius:
15 x outer diameter
To be doubled during laying operations
Tinned copper conductors available on request
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania