EN 50288-7 XLPE Insulation OS Unarmoured Fire Retardant
EN 50288-7 XLPE Insulation OS Unarmoured Fire Retardant
- Instrumentation cables 170/300 V
- Overall Screen (OS)
- Oil resistant
EN 50288-7 XLPE Insulation OS Unarmoured 1x2x0,5
Nexans ref. 10134649
- Number of pairs: 1
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 2x2x0,5
Nexans ref. 10134650
- Number of pairs: 2
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 5x2x0,5
Nexans ref. 10192908
- Number of pairs: 5
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 10x2x0,5
Nexans ref. 10192911
- Number of pairs: 10
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 20x2x0,5
Nexans ref. 10134655
- Number of pairs: 20
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 30x2x0,5
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 0.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 1x2x0,75
Nexans ref. 10134657
- Number of pairs: 1
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 2x2x0,75
Nexans ref. 10134658
- Number of pairs: 2
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 5x2x0,75
Nexans ref. 10192957
- Number of pairs: 5
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 10x2x0,75
Nexans ref. 10192960
- Number of pairs: 10
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 20x2x0,75
Nexans ref. 10134663
- Number of pairs: 20
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 30x2x0,75
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 0.75 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 1x2x1
Nexans ref. 10134665
- Number of pairs: 1
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 2x2x1
Nexans ref. 10134666
- Number of pairs: 2
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 5x2x1
Nexans ref. 10192966
- Number of pairs: 5
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 10x2x1
Nexans ref. 10192970
- Number of pairs: 10
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 20x2x1
Nexans ref. 10134671
- Number of pairs: 20
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 30x2x1
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 1 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 1x2x1,5
Nexans ref. 10134673
- Number of pairs: 1
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 2x2x1,5
Nexans ref. 10134674
- Number of pairs: 2
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 5x2x1,5
Nexans ref. 10192976
- Number of pairs: 5
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 10x2x1,5
Nexans ref. 10134679
- Number of pairs: 10
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 20x2x1,5
Nexans ref. 10164840
- Number of pairs: 20
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 30x2x1,5
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 1.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 1x2x2,5
Nexans ref. 10192983
- Number of pairs: 1
- Conductor cross-section: 2.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 2x2x2,5
Nexans ref. 10192984
- Number of pairs: 2
- Conductor cross-section: 2.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 5x2x2,5
Nexans ref. 10192987
- Number of pairs: 5
- Conductor cross-section: 2.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 10x2x2,5
Nexans ref. 10192991
- Number of pairs: 10
- Conductor cross-section: 2.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 20x2x2,5
Nexans ref. 10192997
- Number of pairs: 20
- Conductor cross-section: 2.5 mm²
EN 50288-7 XLPE Insulation OS Unarmoured 30x2x2,5
Nexans ref.
- Number of pairs: 30
- Conductor cross-section: 2.5 mm²
Description
Description
Standards
-
TestIEC 60332-3-22 Cat.A
Applications
These instrumentation and communication cable are used to transmit analogue or digital signals in measurement and process control where chemicals may be present.
Design
Conductor:
Stranded bare copper class 2
Insulation:
Cross-linked polyethylene (XLPE)
Overall screen:
Polyester tape
Tinned copper drain wire
Aluminium backed polyester tape
Outer sheath:
Polyvinyl chloride (PVC).
Colour: black.
Other colour on request.
Core identification
Pair: white - black
Quad: white - black - red - blue (2 pair cables assembled as a quad)
White core printed with pair number
Marking
NEXANS 279 XLPE/OA.SCR/PVC 170/300V Nber of pairs & cross-section Cu IEC 60332-3-22(A) MM YYYY Manufacturing number + metric marking
Standards
EN 50288-7 (Design guide-lines)
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Documentation
Selling & delivery Information
Other fire performances IEC 60332-1 or IEC 60332-3-24(C) and enhanced hydrocarbon resistance on request.
Minimum bending radius:
10 x outer diameter
To be doubled during laying operations
Tinned copper conductors available on request
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania