03 - IP - 09 - EI - SF

Description

Description

Standards

  • Test
    IEC 60332-3-22 Cat.A

Applications

These instrumentation and communication cable are used to transmit analogue or digital signals in measurement and process control where chemicals may be present. The individual screening of each pair limits the consequence of crosstalk.

Nexans code

- 1st serie = number of pairs, triples or quads: 01 to 27
- 2nd serie = pair (IP), triple (IT), quad (IQ)
- 3rd serie = conductor 05 (1 x 0.8 mm), 09 (7 x 0.4 mm) or 15 (7 x 0.52 mm)
- 4th serie = overall screen (EG), individual screen + overall screen (EI)
- 5th serie = mechanical protection: without metal tape (SF), with steel tape (FA), with lead and steel tape (PF)

Design

Conductor:
- Solid plain copper 0.50 mm² (1 x 0.80 mm) or stranded plain copper cross-section 0.88 mm² (7 x 0.40 mm)
Insulation:
- Polyvinyl chloride (PVC)
Indivudual screen:
- Polyester tape
- Tinned copper drain wire
- Aluminium/polyester tape
Individual sheath:
- Polyvinyl chloride (PVC)
Collective screen:
- Polyester tape
- Tinned copper drain wire
- Aluminium/polyester tape
Outer sheath:
- Polyvinyl chloride (PVC)
- Colour: light-blue or grey

Core identification

Pair: natural - red
Triple: natural - red - blue
Blue individual sheath printed with pair or triple number

Marking

NEXANS 279 - Number of pair/triples IP/IT 05/09 EI SF IEC 60332-3-22(A) + metric marking

Electrical Data NF M 87202

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Plain copper
Insulation
PVC
Individual screen
Tinned copper drain wire + aluminium/polyester tape
Individual sheath
PVC
Overall screen
Tinned copper drain wire + aluminium/polyester tape
Outer sheath
PVC

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
0.88 mm²
Number of pairs
3
Number of triples
-
Conductor diameter
1.2 mm
Diameter over insulation
2.2 mm
Minimum outer diameter
13.5 mm
Maximum outer diameter
15.5 mm
Approximate weight
270 kg/km

Electrical characteristics

Electrical characteristics

Operating voltage
250 V

Usage characteristics

Usage characteristics

Fire retardant
EN IEC 60332-3-22 (cat A)
Chemical resistance
Hydrocarbons resistant
Electro magnetic interference resistance
Yes
Operating temperature, range
-20 ... 60 °C
Max. conductor temperature in service
70 °C
Standard
NFM

Resources

Resources

Selling & delivery Information

Minimum bending radius:

10 x outer diameter
To be doubled during laying operations

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close