AFNOR NF M 87-202 OS Unarmoured
Fire retardant
AFNOR NF M 87-202 OS Unarmoured
Fire retardant
- Instrumentation cables 250 V
- Overall Screen (OS)
- Hydrocarbons resistant
03 IP 05 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.5 mm²
- Number of pairs: 3
- Number of triples: -
07 IP 05 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.5 mm²
- Number of pairs: 7
- Number of triples: -
12 IP 05 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.5 mm²
- Number of pairs: 12
- Number of triples: -
19 IP 05 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.5 mm²
- Number of pairs: 19
- Number of triples: -
27 IP 05 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.5 mm²
- Number of pairs: 27
- Number of triples: -
07 IT 05 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.5 mm²
- Number of pairs: -
- Number of triples: 7
12 IT 05 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.5 mm²
- Number of pairs: -
- Number of triples: 12
01 IP 09 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.88 mm²
- Number of pairs: 1
- Number of triples: -
01 IT 09 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.88 mm²
- Number of pairs: -
- Number of triples: 1
01 IQ 09 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.88 mm²
- Number of pairs: -
- Number of triples: -
03 IP 09 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.88 mm²
- Number of pairs: 3
- Number of triples: -
07 IP 09 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.88 mm²
- Number of pairs: 7
- Number of triples: -
12 IP 09 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.88 mm²
- Number of pairs: 12
- Number of triples: -
19 IP 09 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.88 mm²
- Number of pairs: 19
- Number of triples: -
27 IP 09 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.88 mm²
- Number of pairs: 27
- Number of triples: -
07 IT 09 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.88 mm²
- Number of pairs: -
- Number of triples: 7
12 IT 09 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 0.88 mm²
- Number of pairs: -
- Number of triples: 12
01 IP 15 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 1.5 mm²
- Number of pairs: 1
- Number of triples: -
01 IT 15 EG SF
Nexans ref.
- Packaging: Cut to length (m)
- Conductor cross-section: 1.5 mm²
- Number of pairs: -
- Number of triples: 1
Description
Description
Standards
-
TestIEC 60332-3-22 Cat.A
Applications
These instrumentation and communication cables are used to transmit analogue or digital signals in measurement and process control where hydrocarbons may be present.
Nexans code
1st serie = number of pairs, triples or quads: 01 to 27
2nd serie = pair (IP), triple (IT), quad (IQ)
3rd serie = conductor 05 (1 x 0.8 mm), 09 (7 x 0.4 mm) or 15 (7 x 0.52 mm)
4th serie = overall screen (EG), individual screen + overall screen (EI)
5th serie = mechanical protection: without metal tape (SF), with steel tape (FA), with lead and steel tape (PF)
Design
Conductor:
- Solid plain copper 0.50 mm² (1 x 0.80 mm) or stranded plain copper cross-section 0.88 mm² (7 x 0.40 mm) or 1.5 mm² (7 x 0.52 mm)
Insulation:
- Polyvinyl chloride (PVC)
Overall screen:
- Polyester tape
- Tinned copper drain wire
- Aluminium/polyester tape
Outer sheath:
- Polyvinyl chloride (PVC)
- Colour: light-blue or grey
Core identification
Pair: natural - red
Triple: natural - red - blue
Quad: natural - red - blue - yellow
Natural cores printed with pair/triple number
Marking
NEXANS 279 - Number of pair/triple/quad IP/IT/IQ 05/09/15 EG SF IEC 60332-3-22(A) + metric marking
Electrical Data NF M 87202
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Minimum bending radius:
10 x outer diameter
To be doubled during laying operations
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania