IEC MV, XLPE Insulation, CWS, Lead, PVC (1C)
IEC MV, XLPE Insulation, CWS, Lead, PVC (1C)
Single-core XLPE-insulated cables with PVC sheath
Read more1x120
Nexans ref. 21120CXCVUB09DO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 30.0 mm
- Approximate weight: 2700 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x120
Nexans ref. 21120CXCVUB09EO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 32.0 mm
- Approximate weight: 2900 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x120
Nexans ref. 21120CXCVUB09GO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 35.0 mm
- Approximate weight: 3100 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x120
Nexans ref. 21120CXCVUB09HO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 36.0 mm
- Approximate weight: 3300 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x120
Nexans ref. 21120CXCVUB09JO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 41.0 mm
- Approximate weight: 3590 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x150
Nexans ref. 21150CXCVUB09DO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 31.0 mm
- Approximate weight: 3060 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x150
Nexans ref. 21150CXCVUB09EO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 33.0 mm
- Approximate weight: 3200 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x150
Nexans ref. 21150CXCVUB09GO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 36.0 mm
- Approximate weight: 3430 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x150
Nexans ref. 21150CXCVUB09HO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 37.0 mm
- Approximate weight: 3620 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x150
Nexans ref. 21150CXCVUB09JO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 42.0 mm
- Approximate weight: 4140 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x185
Nexans ref. 21185CXCVUB09DO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 33.0 mm
- Approximate weight: 3560 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x185
Nexans ref. 21185CXCVUB09EO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 35.0 mm
- Approximate weight: 3770 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x185
Nexans ref. 21185CXCVUB09GO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 37.0 mm
- Approximate weight: 3970 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x185
Nexans ref. 21185CXCVUB09HO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 40.0 mm
- Approximate weight: 4160 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x185
Nexans ref. 21185CXCVUB09JO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 45.0 mm
- Approximate weight: 4980 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x240
Nexans ref. 21240CXCVUB09DO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 36.0 mm
- Approximate weight: 3800 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x240
Nexans ref. 21240CXCVUB09EO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 39.0 mm
- Approximate weight: 4000 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x240
Nexans ref. 21240CXCVUB09GO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 40.0 mm
- Approximate weight: 4200 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x240
Nexans ref. 21240CXCVUB09HO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 44.0 mm
- Approximate weight: 4400 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x240
Nexans ref. 21240CXCVUB09JO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 49.0 mm
- Approximate weight: 4750 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x25
Nexans ref. 21025CXCVUB09DO0
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 23.0 mm
- Approximate weight: 1295 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x25
Nexans ref. 21025CXCVUB09EO0
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 24.0 mm
- Approximate weight: 1415 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x25
Nexans ref. 21025CXCVUB09GO0
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 27.0 mm
- Approximate weight: 1555 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x300
Nexans ref. 21300CXCVUB09DO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 40.0 mm
- Approximate weight: 4370 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x300
Nexans ref. 21300CXCVUB09EO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 41.0 mm
- Approximate weight: 4450 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x300
Nexans ref. 21300CXCVUB09GO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 44.0 mm
- Approximate weight: 4640 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x300
Nexans ref. 21300CXCVUB09HO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 46.0 mm
- Approximate weight: 4990 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x300
Nexans ref. 21300CXCVUB09JO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 52.0 mm
- Approximate weight: 5555 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x35
Nexans ref. 21035CXCVUB09DO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 24.0 mm
- Approximate weight: 1470 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x35
Nexans ref. 21035CXCVUB09EO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 26.0 mm
- Approximate weight: 1580 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x35
Nexans ref. 21035CXCVUB09GO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 28.0 mm
- Approximate weight: 1760 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x35
Nexans ref. 21035CXCVUB09HO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 30.0 mm
- Approximate weight: 1915 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x400
Nexans ref. 21400CXCVUB09DO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 44.0 mm
- Approximate weight: 5470 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x400
Nexans ref. 21400CXCVUB09EO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 44.0 mm
- Approximate weight: 5460 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x400
Nexans ref. 21400CXCVUB09GO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 49.0 mm
- Approximate weight: 5930 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x400
Nexans ref. 21400CXCVUB09HO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 50.0 mm
- Approximate weight: 6140 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x400
Nexans ref. 21400CXCVUB09JO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 55.0 mm
- Approximate weight: 6580 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x50
Nexans ref. 21050CXCVUB09DO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 26.0 mm
- Approximate weight: 1700 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x50
Nexans ref. 21050CXCVUB09EO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 28.0 mm
- Approximate weight: 1820 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x50
Nexans ref. 21050CXCVUB09GO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 29.0 mm
- Approximate weight: 2000 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x50
Nexans ref. 21050CXCVUB09HO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 31.0 mm
- Approximate weight: 2170 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x50
Nexans ref. 21050CXCVUB09JO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 36.0 mm
- Approximate weight: 2800 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x500
Nexans ref. 21500CXCVUB09DO0
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 48.0 mm
- Approximate weight: 6890 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x500
Nexans ref. 21500CXCVUB09EO0
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 49.0 mm
- Approximate weight: 6930 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x500
Nexans ref. 21500CXCVUB09GO0
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 51.0 mm
- Approximate weight: 7110 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x500
Nexans ref. 21500CXCVUB09HO0
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 52.0 mm
- Approximate weight: 7350 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x500
Nexans ref. 21500CXCVUB09JO0
- Conductor cross-section: 500 mm²
- Nominal outer diameter: 58.0 mm
- Approximate weight: 7930 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x630
Nexans ref. 21630CXCVUB09DO0
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 52.0 mm
- Approximate weight: 8350 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x630
Nexans ref. 21630CXCVUB09EO0
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 52.0 mm
- Approximate weight: 8400 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x630
Nexans ref. 21630CXCVUB09GO0
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 55.0 mm
- Approximate weight: 8590 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x630
Nexans ref. 21630CXCVUB09HO0
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 56.0 mm
- Approximate weight: 8820 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x630
Nexans ref. 21630CXCVUB09JO0
- Conductor cross-section: 630 mm²
- Nominal outer diameter: 61.0 mm
- Approximate weight: 9506 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x70
Nexans ref. 21070CXCVUB09DO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 28.0 mm
- Approximate weight: 2065 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x70
Nexans ref. 21070CXCVUB09EO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 28.0 mm
- Approximate weight: 2200 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x70
Nexans ref. 21070CXCVUB09GO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 31.0 mm
- Approximate weight: 2390 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x70
Nexans ref. 21070CXCVUB09HO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 33.0 mm
- Approximate weight: 2560 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x70
Nexans ref. 21070CXCVUB09JO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 37.0 mm
- Approximate weight: 3080 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x800
Nexans ref. 21800CXCVUB09DO0
- Conductor cross-section: 800 mm²
- Nominal outer diameter: 56.0 mm
- Approximate weight: 10260 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x800
Nexans ref. 21800CXCVUB09EO0
- Conductor cross-section: 800 mm²
- Nominal outer diameter: 56.0 mm
- Approximate weight: 10300 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x800
Nexans ref. 21800CXCVUB09GO0
- Conductor cross-section: 800 mm²
- Nominal outer diameter: 60.0 mm
- Approximate weight: 10605 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x800
Nexans ref. 21800CXCVUB09HO0
- Conductor cross-section: 800 mm²
- Nominal outer diameter: 61.0 mm
- Approximate weight: 10850 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x800
Nexans ref. 21800CXCVUB09JO0
- Conductor cross-section: 800 mm²
- Nominal outer diameter: 66.0 mm
- Approximate weight: 11445 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x95
Nexans ref. 21095CXCVUB09DO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 28.0 mm
- Approximate weight: 2485 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x95
Nexans ref. 21095CXCVUB09EO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 30.0 mm
- Approximate weight: 2630 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x95
Nexans ref. 21095CXCVUB09GO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 33.0 mm
- Approximate weight: 2810 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x95
Nexans ref. 21095CXCVUB09HO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 35.0 mm
- Approximate weight: 3065 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x95
Nexans ref. 21095CXCVUB09JO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 40.0 mm
- Approximate weight: 3640 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
Description
Description
Standards
-
InternationalIEC 60332-1; IEC 60502-2
Application
These power cables are used for electricity supply in medium voltage installation system. They are well adapted to underground use in industrial application where chemical and mechanical protections are needed.
This group is complying with IEC 60502-2.
Design
1. Conductor
Stranded bare copper class 2 acc. to IEC 60228 or equivalent
2. Insulation
Triple extruded Inner semi conductive layer - Cross Linked Polyethylene 'XLPE' - Outer semi conductive layer
3. Metalic Screen
Copper wire screen with open helix copper tape
4. Metalic Sheath
Extruded Lead
5. Outer Sheath
Polyvinyl Chloride 'PVC'
Options :
- Flame retardant : 'CAT A, CAT B, CATC' to IEC60332 or equivalent.
- Ozone resistant.
- Oil resistant.
- Anti termite.
Sheathing layers can be Halogen Free Flame Retardant "HFFR", or Polyethylene '"PE'
Installation Conditions:
1.Air Temperature : 30 Deg.
2.Ground Temperature : 20 Deg
3.Soil Thermal Resistivity : 1.5 km/w
4.Depth of lay : 0.8 m
All dimensions have tolerance +-7 %
Marking
no. of cores x conductor size mm2 Cu/XLPE/LS/PVC Voltage grade Standard MADE IN QATAR QICC - Nexans Year Meters
Custom marking available
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Note: On request we are delivering three single core laid up cables on one drum
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania