IEC MV, XLPE Insulation, CWS, Lead, SWA, PVC (3C)
IEC MV, XLPE Insulation, CWS, Lead, SWA, PVC (3C)
Multi-core XLPE-insulated cables with PVC sheath
Read more3x120
Nexans ref. 23120CXCVSB09DO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 65.0 mm
- Approximate weight: 11495 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x120
Nexans ref. 23120CXCVSB09EO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 69.0 mm
- Approximate weight: 12245 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x120
Nexans ref. 23120CXCVSB09GO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 74.0 mm
- Approximate weight: 13275 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x120
Nexans ref. 23120CXCVSB09HO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 79.0 mm
- Approximate weight: 14215 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x120
Nexans ref. 23120CXCVSB09JO0
- Conductor cross-section: 120 mm²
- Nominal outer diameter: 91.0 mm
- Approximate weight: 18090 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x150
Nexans ref. 23150CXCVSB09DO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 68.0 mm
- Approximate weight: 13190 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x150
Nexans ref. 23150CXCVSB09EO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 72.0 mm
- Approximate weight: 13995 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x150
Nexans ref. 23150CXCVSB09GO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 77.0 mm
- Approximate weight: 14935 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x150
Nexans ref. 23150CXCVSB09HO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 84.0 mm
- Approximate weight: 17490 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x150
Nexans ref. 23150CXCVSB09JO0
- Conductor cross-section: 150 mm²
- Nominal outer diameter: 94.0 mm
- Approximate weight: 19995 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x185
Nexans ref. 23185CXCVSB09DO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 72.0 mm
- Approximate weight: 15240 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x185
Nexans ref. 23185CXCVSB09EO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 77.0 mm
- Approximate weight: 16055 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x185
Nexans ref. 23185CXCVSB09GO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 84.0 mm
- Approximate weight: 18640 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x185
Nexans ref. 23185CXCVSB09HO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 88.0 mm
- Approximate weight: 19720 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x185
Nexans ref. 23185CXCVSB09JO0
- Conductor cross-section: 185 mm²
- Nominal outer diameter: 98.0 mm
- Approximate weight: 22275 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x240
Nexans ref. 23240CXCVSB09DO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 78.0 mm
- Approximate weight: 18420 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x240
Nexans ref. 23240CXCVSB09EO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 84.0 mm
- Approximate weight: 20765 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x240
Nexans ref. 23240CXCVSB09GO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 89.0 mm
- Approximate weight: 21980 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x240
Nexans ref. 23240CXCVSB09HO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 93.0 mm
- Approximate weight: 23105 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x240
Nexans ref. 23240CXCVSB09JO0
- Conductor cross-section: 240 mm²
- Nominal outer diameter: 104.0 mm
- Approximate weight: 25635 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x25
Nexans ref. 23025CXCVSB09DO0
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 45.0 mm
- Approximate weight: 4740 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x25
Nexans ref.
- Conductor cross-section: - mm²
- Nominal outer diameter: - mm
- Approximate weight: - kg/km
- Rated Voltage Uo/U (Um): -
3x25
Nexans ref. 23025CXCVSB09EO0
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 51.0 mm
- Approximate weight: 5800 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x25
Nexans ref. 23025CXCVSB09GO0
- Conductor cross-section: 25 mm²
- Nominal outer diameter: 56.0 mm
- Approximate weight: 6700 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x300
Nexans ref. 23300CXCVSB09DO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 89.0 mm
- Approximate weight: 24110 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x300
Nexans ref. 23300CXCVSB09EO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 92.0 mm
- Approximate weight: 24865 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x300
Nexans ref. 23300CXCVSB09GO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 97.0 mm
- Approximate weight: 26050 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x300
Nexans ref. 23300CXCVSB09HO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 100.0 mm
- Approximate weight: 26995 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x300
Nexans ref. 23300CXCVSB09JO0
- Conductor cross-section: 300 mm²
- Nominal outer diameter: 112.0 mm
- Approximate weight: 29350 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x35
Nexans ref. 23035CXCVSB09DO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 48.0 mm
- Approximate weight: 5400 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x35
Nexans ref. 23035CXCVSB09EO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 54.0 mm
- Approximate weight: 6700 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x35
Nexans ref. 23035CXCVSB09GO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 60.0 mm
- Approximate weight: 7400 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x35
Nexans ref. 23035CXCVSB09HO0
- Conductor cross-section: 35 mm²
- Nominal outer diameter: 64.0 mm
- Approximate weight: 8280 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x400
Nexans ref. 23400CXCVSB09DO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 96.0 mm
- Approximate weight: 28820 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x400
Nexans ref. 23400CXCVSB09EO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 98.0 mm
- Approximate weight: 29290 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x400
Nexans ref. 23400CXCVSB09GO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 103.0 mm
- Approximate weight: 30310 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x400
Nexans ref. 23400CXCVSB09HO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 107.0 mm
- Approximate weight: 31275 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x400
Nexans ref. 23400CXCVSB09JO0
- Conductor cross-section: 400 mm²
- Nominal outer diameter: 119.0 mm
- Approximate weight: 33570 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x50
Nexans ref. 23050CXCVSB09DO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 52.0 mm
- Approximate weight: 6880 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x50
Nexans ref. 23050CXCVSB09EO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 56.0 mm
- Approximate weight: 7540 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x50
Nexans ref. 23050CXCVSB09GO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 62.0 mm
- Approximate weight: 8310 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x50
Nexans ref. 23050CXCVSB09HO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 67.0 mm
- Approximate weight: 9200 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x50
Nexans ref. 23050CXCVSB09JO0
- Conductor cross-section: 50 mm²
- Nominal outer diameter: 80.0 mm
- Approximate weight: 12550 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x70
Nexans ref. 23070CXCVSB09DO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 58.0 mm
- Approximate weight: 8310 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x70
Nexans ref. 23070CXCVSB09EO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 62.0 mm
- Approximate weight: 8970 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x70
Nexans ref. 23070CXCVSB09GO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 67.0 mm
- Approximate weight: 9950 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x70
Nexans ref. 23070CXCVSB09HO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 71.0 mm
- Approximate weight: 10750 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x70
Nexans ref. 23070CXCVSB09JO0
- Conductor cross-section: 70 mm²
- Nominal outer diameter: 84.0 mm
- Approximate weight: 14500 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
3x95
Nexans ref. 23095CXCVSB09DO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 61.0 mm
- Approximate weight: 9970 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
3x95
Nexans ref. 23095CXCVSB09EO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 66.0 mm
- Approximate weight: 10805 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
3x95
Nexans ref. 23095CXCVSB09GO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 71.0 mm
- Approximate weight: 11720 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
3x95
Nexans ref. 23095CXCVSB09HO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 75.0 mm
- Approximate weight: 12700 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
3x95
Nexans ref. 23095CXCVSB09JO0
- Conductor cross-section: 95 mm²
- Nominal outer diameter: 88.0 mm
- Approximate weight: 16435 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
Description
Description
Standards
-
InternationalIEC 60332-1; IEC 60502-2
Application
These power cables are used for electricity supply in medium voltage installation system. They are well adapted to underground use in industrial application where chemical and mechanical protections are needed. This group is complying with IEC 60502-2.
Design
1. Conductor
Stranded bare copper class 2 acc. to IEC 60228 or equivalent
2. Insulation
Triple extruded Inner semi conductive layer - Cross Linked Polyethylene 'XLPE' - Outer semi conductive layer
3. Metalic Screen
Copper wire screen with open helix copper tape
4. Metal Sheath
Extruded Lead
5. Armour
Galvanized Steel Wire Armour "SWA"
6. Outer Sheath
Polyvinyl Chloride 'PVC'
Options :
- Flame retardant : 'CAT A, CAT B, CATC' to IEC60332 or equivalent.
- Ozone resistant.
- Oil resistant.
- Anti termite.
Sheathing layers can be Halogen Free Flame Retardant "HFFR", or Polyethylene '"PE'
Installation Conditions:
1.Air Temperature : 30 Deg.
2.Ground Temperature : 20 Deg
3.Soil Thermal Resistivity : 1.5 km/w
4.Depth of lay : 0.8 m
All dimensions have tolerance +-7 %
Marking
no. of cores x conductor size mm2 Cu/XLPE/LS/SWA/PVC Voltage grade V Standard MADE IN QATAR QICC - Nexans Year Meters
Custom marking available
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Note: On request we are delivering three single core laid up cables on one drum
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania