IEC/BS MV, XLPE Insulation, CWS, AWA, PVC (1C)
IEC/BS MV, XLPE Insulation, CWS, AWA, PVC (1C)
Single-core XLPE-insulated cables with PVC sheath
Read more1x120
Nexans ref. 21120CXCVAB09DD0
- Conductor cross-section: 120 mm²
- Approximate weight: 2038 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x120
Nexans ref. 21120CXCVAB09ED0
- Conductor cross-section: 120 mm²
- Approximate weight: 2155 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x120
Nexans ref. 21120CXCVAB09GD0
- Conductor cross-section: 120 mm²
- Approximate weight: 2330 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x120
Nexans ref. 21120CXCVAB09HD0
- Conductor cross-section: 120 mm²
- Approximate weight: 2460 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x120
Nexans ref. 21120CXCVAB09JD0
- Conductor cross-section: 120 mm²
- Approximate weight: 2850 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x150
Nexans ref. 21150CXCVAB09DD0
- Conductor cross-section: 150 mm²
- Approximate weight: 2430 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x150
Nexans ref. 21150CXCVAB09ED0
- Conductor cross-section: 150 mm²
- Approximate weight: 2540 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x150
Nexans ref. 21150CXCVAB09GD0
- Conductor cross-section: 150 mm²
- Approximate weight: 2720 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x150
Nexans ref. 21150CXCVAB09HD0
- Conductor cross-section: 150 mm²
- Approximate weight: 2870 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x150
Nexans ref. 21150CXCVAB09JD0
- Conductor cross-section: 150 mm²
- Approximate weight: 3280 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x185
Nexans ref. 21185CXCVAB09DD0
- Conductor cross-section: 185 mm²
- Approximate weight: 2821 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x185
Nexans ref. 21185CXCVAB09ED0
- Conductor cross-section: 185 mm²
- Approximate weight: 2990 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x185
Nexans ref. 21185CXCVAB09GD0
- Conductor cross-section: 185 mm²
- Approximate weight: 3130 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x185
Nexans ref. 21185CXCVAB09HD0
- Conductor cross-section: 185 mm²
- Approximate weight: 3300 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x185
Nexans ref. 21185CXCVAB09JD0
- Conductor cross-section: 185 mm²
- Approximate weight: 3950 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x240
Nexans ref. 21240CXCVAB09DD0
- Conductor cross-section: 240 mm²
- Approximate weight: 3459 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x240
Nexans ref. 21240CXCVAB09ED0
- Conductor cross-section: 240 mm²
- Approximate weight: 3577 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x240
Nexans ref. 21240CXCVAB09GD0
- Conductor cross-section: 240 mm²
- Approximate weight: 3720 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x240
Nexans ref. 21240CXCVAB09HD0
- Conductor cross-section: 240 mm²
- Approximate weight: 3900 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x240
Nexans ref. 21240CXCVAB09JD0
- Conductor cross-section: 240 mm²
- Approximate weight: 4520 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x25
Nexans ref. 21025CXCVAB09DD0
- Conductor cross-section: 25 mm²
- Approximate weight: 926 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x25
Nexans ref. 21025CXCVAB09ED0
- Conductor cross-section: 25 mm²
- Approximate weight: 1010 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x25
Nexans ref. 21025CXCVAB09GD0
- Conductor cross-section: 25 mm²
- Approximate weight: 1110 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x300
Nexans ref. 21300CXCVAB09DD0
- Conductor cross-section: 300 mm²
- Approximate weight: 4160 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x300
Nexans ref. 21300CXCVAB09ED0
- Conductor cross-section: 300 mm²
- Approximate weight: 4240 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x300
Nexans ref. 21300CXCVAB09GD0
- Conductor cross-section: 300 mm²
- Approximate weight: 4420 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x300
Nexans ref. 21300CXCVAB09HD0
- Conductor cross-section: 300 mm²
- Approximate weight: 4750 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x300
Nexans ref. 21300CXCVAB09JD0
- Conductor cross-section: 300 mm²
- Approximate weight: 5290 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x35
Nexans ref. 21035CXCVAB09DD0
- Conductor cross-section: 35 mm²
- Approximate weight: 1051 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x35
Nexans ref. 21035CXCVAB09ED0
- Conductor cross-section: 35 mm²
- Approximate weight: 1130 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x35
Nexans ref. 21035CXCVAB09GD0
- Conductor cross-section: 35 mm²
- Approximate weight: 1260 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x35
Nexans ref. 21035CXCVAB09HD0
- Conductor cross-section: 35 mm²
- Approximate weight: 1370 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x400
Nexans ref. 21400CXCVAB09DD0
- Conductor cross-section: 400 mm²
- Approximate weight: 5209 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x400
Nexans ref. 21400CXCVAB09ED0
- Conductor cross-section: 400 mm²
- Approximate weight: 5200 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x400
Nexans ref. 21400CXCVAB09GD0
- Conductor cross-section: 400 mm²
- Approximate weight: 5650 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x400
Nexans ref. 21400CXCVAB09HD0
- Conductor cross-section: 400 mm²
- Approximate weight: 5850 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x400
Nexans ref. 21400CXCVAB09JD0
- Conductor cross-section: 400 mm²
- Approximate weight: 6270 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x50
Nexans ref. 21050CXCVAB09DD0
- Conductor cross-section: 50 mm²
- Approximate weight: 1215 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x50
Nexans ref. 21050CXCVAB09ED0
- Conductor cross-section: 50 mm²
- Approximate weight: 1300 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x50
Nexans ref. 21050CXCVAB09GD0
- Conductor cross-section: 50 mm²
- Approximate weight: 1430 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x50
Nexans ref. 21050CXCVAB09HD0
- Conductor cross-section: 50 mm²
- Approximate weight: 1550 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x50
Nexans ref. 21050CXCVAB09JD0
- Conductor cross-section: 50 mm²
- Approximate weight: 2000 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x500
Nexans ref. 21500CXCVAB09DD0
- Conductor cross-section: 500 mm²
- Approximate weight: 6559 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x500
Nexans ref. 21500CXCVAB09ED0
- Conductor cross-section: 500 mm²
- Approximate weight: 6600 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x500
Nexans ref. 21500CXCVAB09GD0
- Conductor cross-section: 500 mm²
- Approximate weight: 6770 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x500
Nexans ref. 21500CXCVAB09HD0
- Conductor cross-section: 500 mm²
- Approximate weight: 7000 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x500
Nexans ref. 21500CXCVAB09JD0
- Conductor cross-section: 500 mm²
- Approximate weight: 7550 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x630
Nexans ref. 21630CXCVAB09DD0
- Conductor cross-section: 630 mm²
- Approximate weight: 7950 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x630
Nexans ref. 21630CXCVAB09ED0
- Conductor cross-section: 630 mm²
- Approximate weight: 8000 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x630
Nexans ref. 21630CXCVAB09GD0
- Conductor cross-section: 630 mm²
- Approximate weight: 8180 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x630
Nexans ref. 21630CXCVAB09HD0
- Conductor cross-section: 630 mm²
- Approximate weight: 8400 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x630
Nexans ref. 21630CXCVAB09JD0
- Conductor cross-section: 630 mm²
- Approximate weight: 9050 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x70
Nexans ref. 21070CXCVAB09DD0
- Conductor cross-section: 70 mm²
- Approximate weight: 1473 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x70
Nexans ref. 21070CXCVAB09ED0
- Conductor cross-section: 70 mm²
- Approximate weight: 1570 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x70
Nexans ref. 21070CXCVAB09GD0
- Conductor cross-section: 70 mm²
- Approximate weight: 1710 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x70
Nexans ref. 21070CXCVAB09HD0
- Conductor cross-section: 70 mm²
- Approximate weight: 1830 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x70
Nexans ref. 21070CXCVAB09JD0
- Conductor cross-section: 70 mm²
- Approximate weight: 2200 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x800
Nexans ref. 21800CXCVAB09DD0
- Conductor cross-section: 800 mm²
- Approximate weight: 9778 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x800
Nexans ref. 21800CXCVAB09ED0
- Conductor cross-section: 800 mm²
- Approximate weight: 9810 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x800
Nexans ref. 21800CXCVAB09GD0
- Conductor cross-section: 800 mm²
- Approximate weight: 10100 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x800
Nexans ref. 21800CXCVAB09HD0
- Conductor cross-section: 800 mm²
- Approximate weight: 10330 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x800
Nexans ref. 21800CXCVAB09JD0
- Conductor cross-section: 800 mm²
- Approximate weight: 10900 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
1x95
Nexans ref. 21095CXCVAB09DD0
- Conductor cross-section: 95 mm²
- Approximate weight: 1777 kg/km
- Rated Voltage Uo/U (Um): 3.6 / 6 (7.2) kV
1x95
Nexans ref. 21095CXCVAB09ED0
- Conductor cross-section: 95 mm²
- Approximate weight: 1880 kg/km
- Rated Voltage Uo/U (Um): 6 / 10 (12) kV
1x95
Nexans ref. 21095CXCVAB09GD0
- Conductor cross-section: 95 mm²
- Approximate weight: 2010 kg/km
- Rated Voltage Uo/U (Um): 8.7 / 15 (17.5) kV
1x95
Nexans ref. 21095CXCVAB09HD0
- Conductor cross-section: 95 mm²
- Approximate weight: 2190 kg/km
- Rated Voltage Uo/U (Um): 12 / 20 (24) kV
1x95
Nexans ref. 21095CXCVAB09JD0
- Conductor cross-section: 95 mm²
- Approximate weight: 2600 kg/km
- Rated Voltage Uo/U (Um): 18 / 30 (36) kV
Description
Description
Standards
-
InternationalIEC 60332-1; IEC 60502-2
-
NationalBS 6622
Application
These power cables are used for electricity supply in medium voltage installation system. They are well adapted to underground use in industrial application where chemical and mechanical protections are needed. This group is complying with IEC 60502-2 or BS 6622.
Design
1. Conductor
Stranded bare copper class 2 acc. to IEC 60228 or equivalent
2. Insulation
Triple extruded Inner semi conductive layer - Cross Linked Polyethylene 'XLPE' - Outer semi conductive layer
3. Metalic Screen
Copper wire screen with open helix copper tape
4. Inner Sheathing or Bedding
Extruded PVC
5. Armour
Aluminum Wire Armour "AWA"
6. Outer Sheath
Polyvinyl Chloride 'PVC'
Options :
- Flame retardant : 'CAT A, CAT B, CATC' to IEC60332 or equivalent.
- Ozone resistant.
- Oil resistant.
- Anti termite.
Sheathing layers can be Halogen Free Flame Retardant "HFFR", or Polyethylene '"PE'
Installation Conditions:
1.Air Temperature : 30 Deg.
2.Ground Temperature : 20 Deg
3.Soil Thermal Resistivity : 1.5 km/w
4.Depth of lay : 0.8 m
All dimensions have tolerance +-7 %
Marking
no. of cores x conductor size mm2 Cu/XLPE/AWA/PVC Voltage grade V Standard MADE IN QATAR QICC - Nexans Year Meters
Custom marking available
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Dimensional characteristics
Dimensional characteristics
Mechanical characteristics
Mechanical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Note: On request we are delivering three single core laid up cables on one drum
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania