ALSECURE PLUS® NX400 LV, Mica, XLPE, SWA, HFFR 0.6/1 kV
ALSECURE PLUS® NX400 LV, Mica, XLPE, SWA, HFFR 0.6/1 kV
Galvanized steel wire armoured LV cable, HFFR sheathed for fixed installations. Rated voltage 0.6/1 KV
Read more2x1.5
Nexans ref. 22002RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 2
- Conductor cross-section: 1.5 mm²
- Approximate weight: 290 kg/km
- Nominal outer diameter: 13.0 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 25 A
- Permissible current rating when buried: 23 A
- Voltage drop, 3 conductors: 22.8 V/A.km
2x10
Nexans ref. 22010RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 2
- Conductor cross-section: 10 mm²
- Approximate weight: 720 kg/km
- Nominal outer diameter: 19.0 mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 78 A
- Permissible current rating when buried: 65 A
- Voltage drop, 3 conductors: 3.5 V/A.km
2x120
Nexans ref. 22120RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 2
- Conductor cross-section: 120 mm²
- Approximate weight: 4330 kg/km
- Nominal outer diameter: 44.0 mm
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 353 A
- Permissible current rating when buried: 257 A
- Voltage drop, 3 conductors: 0.37 V/A.km
2x150
Nexans ref. 22150RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 2
- Conductor cross-section: 150 mm²
- Approximate weight: 5140 kg/km
- Nominal outer diameter: 47.0 mm
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 406 A
- Permissible current rating when buried: 287 A
- Voltage drop, 3 conductors: 0.3 V/A.km
2x16
Nexans ref. 22016RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 2
- Conductor cross-section: 16 mm²
- Approximate weight: 900 kg/km
- Nominal outer diameter: 21.0 mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 99 A
- Permissible current rating when buried: 84 A
- Voltage drop, 3 conductors: 2.2 V/A.km
2x185
Nexans ref. 22185RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 2
- Conductor cross-section: 185 mm²
- Approximate weight: 6650 kg/km
- Nominal outer diameter: 54.0 mm
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- Permissible current rating in open air: 463 A
- Permissible current rating when buried: 324 A
- Voltage drop, 3 conductors: 0.26 V/A.km
2x2.5
Nexans ref. 22003RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 2
- Conductor cross-section: 2.5 mm²
- Approximate weight: 340 kg/km
- Nominal outer diameter: 14.0 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 30 A
- Voltage drop, 3 conductors: 14.0 V/A.km
2x25
Nexans ref. 22025RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 2
- Conductor cross-section: 25 mm²
- Approximate weight: 1350 kg/km
- Nominal outer diameter: 25.0 mm
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 131 A
- Permissible current rating when buried: 107 A
- Voltage drop, 3 conductors: 1.65 V/A.km
2x35
Nexans ref. 22035RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 2
- Conductor cross-section: 35 mm²
- Approximate weight: 1610 kg/km
- Nominal outer diameter: 27.0 mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 162 A
- Permissible current rating when buried: 129 A
- Voltage drop, 3 conductors: 1.15 V/A.km
2x4
Nexans ref. 22004RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 2
- Conductor cross-section: 4 mm²
- Approximate weight: 400 kg/km
- Nominal outer diameter: 15.0 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 44 A
- Permissible current rating when buried: 39 A
- Voltage drop, 3 conductors: 8.7 V/A.km
2x50
Nexans ref. 22050RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 2
- Conductor cross-section: 50 mm²
- Approximate weight: 2010 kg/km
- Nominal outer diameter: 31.0 mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 197 A
- Permissible current rating when buried: 153 A
- Voltage drop, 3 conductors: 0.89 V/A.km
2x6
Nexans ref. 22006RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 2
- Conductor cross-section: 6 mm²
- Approximate weight: 470 kg/km
- Nominal outer diameter: 17.0 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 56 A
- Permissible current rating when buried: 49 A
- Voltage drop, 3 conductors: 5.9 V/A.km
2x70
Nexans ref. 22070RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 2
- Conductor cross-section: 70 mm²
- Approximate weight: 2640 kg/km
- Nominal outer diameter: 35.0 mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 251 A
- Permissible current rating when buried: 188 A
- Voltage drop, 3 conductors: 0.6 V/A.km
2x95
Nexans ref. 22095RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 2
- Conductor cross-section: 95 mm²
- Approximate weight: 3630 kg/km
- Nominal outer diameter: 40.0 mm
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 304 A
- Permissible current rating when buried: 226 A
- Voltage drop, 3 conductors: 0.45 V/A.km
3x1.5
Nexans ref. 23002RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 3
- Conductor cross-section: 1.5 mm²
- Approximate weight: 340 kg/km
- Nominal outer diameter: 14.0 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 25 A
- Permissible current rating when buried: 23 A
- Voltage drop, 3 conductors: 22.8 V/A.km
3x10
Nexans ref. 23010RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 3
- Conductor cross-section: 10 mm²
- Approximate weight: 890 kg/km
- Nominal outer diameter: 20.0 mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 78 A
- Permissible current rating when buried: 65 A
- Voltage drop, 3 conductors: 3.5 V/A.km
3x120
Nexans ref. 23120RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 3
- Conductor cross-section: 120 mm²
- Approximate weight: 5520 kg/km
- Nominal outer diameter: 42.0 mm
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 353 A
- Permissible current rating when buried: 257 A
- Voltage drop, 3 conductors: 0.37 V/A.km
3x150
Nexans ref. 23150RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 3
- Conductor cross-section: 150 mm²
- Approximate weight: 7030 kg/km
- Nominal outer diameter: 48.0 mm
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 406 A
- Permissible current rating when buried: 287 A
- Voltage drop, 3 conductors: 0.3 V/A.km
3x16
Nexans ref. 23016RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 3
- Conductor cross-section: 16 mm²
- Approximate weight: 1150 kg/km
- Nominal outer diameter: 22.0 mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 99 A
- Permissible current rating when buried: 84 A
- Voltage drop, 3 conductors: 2.2 V/A.km
3x185
Nexans ref. 23185RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 3
- Conductor cross-section: 185 mm²
- Approximate weight: 8410 kg/km
- Nominal outer diameter: 52.0 mm
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- Permissible current rating in open air: 463 A
- Permissible current rating when buried: 324 A
- Voltage drop, 3 conductors: 0.26 V/A.km
3x2.5
Nexans ref. 23003RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 3
- Conductor cross-section: 2.5 mm²
- Approximate weight: 400 kg/km
- Nominal outer diameter: 15.0 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 30 A
- Voltage drop, 3 conductors: 14.0 V/A.km
3x240
Nexans ref. 23240RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 3
- Conductor cross-section: 240 mm²
- Approximate weight: 10480 kg/km
- Nominal outer diameter: 58.0 mm
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
- Permissible current rating in open air: 546 A
- Permissible current rating when buried: 375 A
- Voltage drop, 3 conductors: 0.21 V/A.km
3x25
Nexans ref. 23025RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 3
- Conductor cross-section: 25 mm²
- Approximate weight: 1700 kg/km
- Nominal outer diameter: 27.0 mm
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 131 A
- Permissible current rating when buried: 107 A
- Voltage drop, 3 conductors: 1.65 V/A.km
3x300
Nexans ref. 23300RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 3
- Conductor cross-section: 300 mm²
- Approximate weight: 12770 kg/km
- Nominal outer diameter: 63.0 mm
- Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
- Permissible current rating in open air: 628 A
- Permissible current rating when buried: 419 A
- Voltage drop, 3 conductors: 0.18 V/A.km
3x35
Nexans ref. 23035RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 3
- Conductor cross-section: 35 mm²
- Approximate weight: 2070 kg/km
- Nominal outer diameter: 30.0 mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 162 A
- Permissible current rating when buried: 129 A
- Voltage drop, 3 conductors: 1.15 V/A.km
3x4
Nexans ref. 23004RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 3
- Conductor cross-section: 4 mm²
- Approximate weight: 480 kg/km
- Nominal outer diameter: 17.0 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 44 A
- Permissible current rating when buried: 39 A
- Voltage drop, 3 conductors: 8.7 V/A.km
3x400
Nexans ref. 23400RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 3
- Conductor cross-section: 400 mm²
- Approximate weight: 15830 kg/km
- Nominal outer diameter: 70.0 mm
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Permissible current rating in open air: 731 A
- Permissible current rating when buried: 439 A
- Voltage drop, 3 conductors: 0.17 V/A.km
3x50
Nexans ref. 23050RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 3
- Conductor cross-section: 50 mm²
- Approximate weight: 2520 kg/km
- Nominal outer diameter: 30.0 mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 197 A
- Permissible current rating when buried: 153 A
- Voltage drop, 3 conductors: 0.89 V/A.km
3x6
Nexans ref. 23006RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 3
- Conductor cross-section: 6 mm²
- Approximate weight: 580 kg/km
- Nominal outer diameter: 18.0 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 56 A
- Permissible current rating when buried: 49 A
- Voltage drop, 3 conductors: 5.9 V/A.km
3x70
Nexans ref. 23070RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 3
- Conductor cross-section: 70 mm²
- Approximate weight: 3570 kg/km
- Nominal outer diameter: 35.0 mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 251 A
- Permissible current rating when buried: 188 A
- Voltage drop, 3 conductors: 0.6 V/A.km
3x95
Nexans ref. 23095RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 3
- Conductor cross-section: 95 mm²
- Approximate weight: 4570 kg/km
- Nominal outer diameter: 39.0 mm
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 304 A
- Permissible current rating when buried: 226 A
- Voltage drop, 3 conductors: 0.45 V/A.km
4x1.5
Nexans ref. 24002RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 4
- Conductor cross-section: 1.5 mm²
- Approximate weight: 200 kg/km
- Nominal outer diameter: 13.0 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 25 A
- Permissible current rating when buried: 23 A
- Voltage drop, 3 conductors: 22.8 V/A.km
4x10
Nexans ref. 24010RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 4
- Conductor cross-section: 10 mm²
- Approximate weight: 1060 kg/km
- Nominal outer diameter: 21.0 mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 78 A
- Permissible current rating when buried: 65 A
- Voltage drop, 3 conductors: 3.5 V/A.km
4x120
Nexans ref. 24120RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 4
- Conductor cross-section: 120 mm²
- Approximate weight: 7280 kg/km
- Nominal outer diameter: 47.0 mm
- Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
- Permissible current rating in open air: 353 A
- Permissible current rating when buried: 257 A
- Voltage drop, 3 conductors: 0.37 V/A.km
4x150
Nexans ref. 24150RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 4
- Conductor cross-section: 150 mm²
- Approximate weight: 8700 kg/km
- Nominal outer diameter: 52.0 mm
- Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
- Permissible current rating in open air: 406 A
- Permissible current rating when buried: 287 A
- Voltage drop, 3 conductors: 0.3 V/A.km
4x16
Nexans ref. 24016RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 4
- Conductor cross-section: 16 mm²
- Approximate weight: 1500 kg/km
- Nominal outer diameter: 25.0 mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 99 A
- Permissible current rating when buried: 84 A
- Voltage drop, 3 conductors: 2.2 V/A.km
4x185
Nexans ref. 24185RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 4
- Conductor cross-section: 185 mm²
- Approximate weight: 10570 kg/km
- Nominal outer diameter: 57.0 mm
- Max. DC resistance of the conductor at 20°C: 0.0991 Ohm/km
- Permissible current rating in open air: 463 A
- Permissible current rating when buried: 324 A
- Voltage drop, 3 conductors: 0.26 V/A.km
4x2.5
Nexans ref. 24003RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 4
- Conductor cross-section: 2.5 mm²
- Approximate weight: 420 kg/km
- Nominal outer diameter: 15.0 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 30 A
- Voltage drop, 3 conductors: 14.0 V/A.km
4x240
Nexans ref. 24240RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 4
- Conductor cross-section: 240 mm²
- Approximate weight: 13370 kg/km
- Nominal outer diameter: 64.0 mm
- Max. DC resistance of the conductor at 20°C: 0.0754 Ohm/km
- Permissible current rating in open air: 546 A
- Permissible current rating when buried: 375 A
- Voltage drop, 3 conductors: 0.21 V/A.km
4x25
Nexans ref. 24025RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 4
- Conductor cross-section: 25 mm²
- Approximate weight: 2070 kg/km
- Nominal outer diameter: 30.0 mm
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 131 A
- Permissible current rating when buried: 107 A
- Voltage drop, 3 conductors: 1.65 V/A.km
4x300
Nexans ref. 24300RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 4
- Conductor cross-section: 300 mm²
- Approximate weight: 16230 kg/km
- Nominal outer diameter: 71.0 mm
- Max. DC resistance of the conductor at 20°C: 0.0601 Ohm/km
- Permissible current rating in open air: 628 A
- Permissible current rating when buried: 419 A
- Voltage drop, 3 conductors: 0.18 V/A.km
4x35
Nexans ref. 24035RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 4
- Conductor cross-section: 35 mm²
- Approximate weight: 2550 kg/km
- Nominal outer diameter: 32.0 mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 162 A
- Permissible current rating when buried: 129 A
- Voltage drop, 3 conductors: 1.15 V/A.km
4x4
Nexans ref. 24004RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 4
- Conductor cross-section: 4 mm²
- Approximate weight: 510 kg/km
- Nominal outer diameter: 17.0 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 44 A
- Permissible current rating when buried: 39 A
- Voltage drop, 3 conductors: 8.7 V/A.km
4x400
Nexans ref. 24400RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 4
- Conductor cross-section: 400 mm²
- Approximate weight: 21230 kg/km
- Nominal outer diameter: 79.0 mm
- Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
- Permissible current rating in open air: 731 A
- Permissible current rating when buried: 439 A
- Voltage drop, 3 conductors: 0.17 V/A.km
4x50
Nexans ref. 24050RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 4
- Conductor cross-section: 50 mm²
- Approximate weight: 3080 kg/km
- Nominal outer diameter: 32.0 mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 197 A
- Permissible current rating when buried: 153 A
- Voltage drop, 3 conductors: 0.89 V/A.km
4x6
Nexans ref. 24006RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 4
- Conductor cross-section: 6 mm²
- Approximate weight: 750 kg/km
- Nominal outer diameter: 19.0 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 56 A
- Permissible current rating when buried: 49 A
- Voltage drop, 3 conductors: 5.9 V/A.km
4x70
Nexans ref. 24070RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 4
- Conductor cross-section: 70 mm²
- Approximate weight: 4420 kg/km
- Nominal outer diameter: 38.0 mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 251 A
- Permissible current rating when buried: 188 A
- Voltage drop, 3 conductors: 0.6 V/A.km
4x95
Nexans ref. 24095RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Sector-shaped
- Number of cores: 4
- Conductor cross-section: 95 mm²
- Approximate weight: 5650 kg/km
- Nominal outer diameter: 41.0 mm
- Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
- Permissible current rating in open air: 304 A
- Permissible current rating when buried: 226 A
- Voltage drop, 3 conductors: 0.45 V/A.km
5x1.5
Nexans ref. 25002RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 5
- Conductor cross-section: 1.5 mm²
- Approximate weight: 450 kg/km
- Nominal outer diameter: 15.0 mm
- Max. DC resistance of the conductor at 20°C: 12.1 Ohm/km
- Permissible current rating in open air: 25 A
- Permissible current rating when buried: 23 A
- Voltage drop, 3 conductors: 22.8 V/A.km
5x10
Nexans ref. 25010RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 5
- Conductor cross-section: 10 mm²
- Approximate weight: 1250 kg/km
- Nominal outer diameter: 24.0 mm
- Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
- Permissible current rating in open air: 78 A
- Permissible current rating when buried: 65 A
- Voltage drop, 3 conductors: 3.5 V/A.km
5x16
Nexans ref. 25016RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 5
- Conductor cross-section: 16 mm²
- Approximate weight: 1780 kg/km
- Nominal outer diameter: 27.0 mm
- Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
- Permissible current rating in open air: 99 A
- Permissible current rating when buried: 84 A
- Voltage drop, 3 conductors: 2.2 V/A.km
5x2.5
Nexans ref. 25003RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 5
- Conductor cross-section: 2.5 mm²
- Approximate weight: 540 kg/km
- Nominal outer diameter: 17.0 mm
- Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
- Permissible current rating in open air: 33 A
- Permissible current rating when buried: 30 A
- Voltage drop, 3 conductors: 14.0 V/A.km
5x25
Nexans ref. 25025RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 5
- Conductor cross-section: 25 mm²
- Approximate weight: 2490 kg/km
- Nominal outer diameter: 32.0 mm
- Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
- Permissible current rating in open air: 131 A
- Permissible current rating when buried: 107 A
- Voltage drop, 3 conductors: 1.65 V/A.km
5x35
Nexans ref. 25035RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 5
- Conductor cross-section: 35 mm²
- Approximate weight: 3040 kg/km
- Nominal outer diameter: 34.0 mm
- Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
- Permissible current rating in open air: 162 A
- Permissible current rating when buried: 129 A
- Voltage drop, 3 conductors: 1.15 V/A.km
5x4
Nexans ref. 25004RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 5
- Conductor cross-section: 4 mm²
- Approximate weight: 770 kg/km
- Nominal outer diameter: 19.0 mm
- Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
- Permissible current rating in open air: 44 A
- Permissible current rating when buried: 39 A
- Voltage drop, 3 conductors: 8.7 V/A.km
5x50
Nexans ref. 25050RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 5
- Conductor cross-section: 50 mm²
- Approximate weight: 4180 kg/km
- Nominal outer diameter: 40.0 mm
- Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
- Permissible current rating in open air: 197 A
- Permissible current rating when buried: 153 A
- Voltage drop, 3 conductors: 0.89 V/A.km
5x6
Nexans ref. 25006RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 5
- Conductor cross-section: 6 mm²
- Approximate weight: 940 kg/km
- Nominal outer diameter: 21.0 mm
- Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
- Permissible current rating in open air: 56 A
- Permissible current rating when buried: 49 A
- Voltage drop, 3 conductors: 5.9 V/A.km
5x70
Nexans ref. 25070RXZHSH34BD0
- Packaging: Cut to length (m)
- Conductor shape: Circular
- Number of cores: 5
- Conductor cross-section: 70 mm²
- Approximate weight: 5600 kg/km
- Nominal outer diameter: 46.0 mm
- Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
- Permissible current rating in open air: 251 A
- Permissible current rating when buried: 188 A
- Voltage drop, 3 conductors: 0.6 V/A.km
Description
Description
Standards
-
ProductBS 7846
-
TestBS 6387 CWZ; IEC 60331-1 or 2
Applications
Refineries, Mines, Hotels, Schools, Tunnels, High construction, Hospitals, Power plants, Data processing centers, Business centers where there is concentration of sensitive to fire
Construction
Conductor
Stranded bare copper class 2 acc. to EN 60228
Fire Barrier
Mica Glass tape
Insulation
Cross Linked Polyethylene "XLPE"
Inner Sheath or Bedding
Lapped bedding or extruded HFFR
Armour
Galvanized Steel Wire Armour "SWA"
Outer Sheath
Halogen Free Flame retardant "HFFR".
Options :
- Flame retardant : "CAT A, CAT B, CAT C" to BS 4066 or equivalent.
- Ozone resistant.
- Oil resistant.
- Anti termite.
Fire test :
As per BS 6387 :
C-Resistance to fire at 950 Deg for 180 mins.
W-Resistanace to fire and water at 650 Deg for 30 mins.
Z-Resistance to fire and mechanical shock at 950 Deg for 15 mins.
Installation conditions
- Air Temperature : 30 Deg.
- Ground Temperature: 20 Deg.
- Soil Thermal Resistivity : 2.5 k.m/w
- Depth of lay : 0.7 m
All dimensions have tolerance +- 7 %
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Electrical characteristics
Electrical characteristics
Usage characteristics
Usage characteristics
Resources
Resources
Selling & delivery Information
Marking
no. of cores x conductor sizes mm2 Cu / Mica / XLPE / SWA / HFFR 600/1000 V BS 7846 BS 6387 LPCB MADE IN QATAR QICC-Nexans Year Meters
Custom marking available
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania