ALSECURE PLUS® NX100 BS, Cu/Mica/XL-HFFR

Products

1x2.5

Nexans ref. 21003PHZOU000BD0

  • Conductor cross-section: 2.5 mm²
  • Nominal outer diameter: 3.7 mm
  • Approximate weight: 30 kg/km
  • Max. DC resistance of the conductor at 20°C: 7.41 Ohm/km
  • Permissible current rating in open air: 43 A
  • Voltage Drop: 13.8 V/A.km

 

1x4

Nexans ref. 21004PHZOU000BD0

  • Conductor cross-section: 4 mm²
  • Nominal outer diameter: 4.2 mm
  • Approximate weight: 40 kg/km
  • Max. DC resistance of the conductor at 20°C: 4.61 Ohm/km
  • Permissible current rating in open air: 56 A
  • Voltage Drop: 8.6 V/A.km

 

1x6

Nexans ref. 21006PHZOU000BD0

  • Conductor cross-section: 6 mm²
  • Nominal outer diameter: 4.8 mm
  • Approximate weight: 60 kg/km
  • Max. DC resistance of the conductor at 20°C: 3.08 Ohm/km
  • Permissible current rating in open air: 71 A
  • Voltage Drop: 5.8 V/A.km

 

1x10

Nexans ref. 21010PHZOU000BD0

  • Conductor cross-section: 10 mm²
  • Nominal outer diameter: 6.0 mm
  • Approximate weight: 110 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.83 Ohm/km
  • Permissible current rating in open air: 97 A
  • Voltage Drop: 3.5 V/A.km

 

1x16

Nexans ref. 21016PHZOU000BD0

  • Conductor cross-section: 16 mm²
  • Nominal outer diameter: 6.5 mm
  • Approximate weight: 170 kg/km
  • Max. DC resistance of the conductor at 20°C: 1.15 Ohm/km
  • Permissible current rating in open air: 130 A
  • Voltage Drop: 2.2 V/A.km

 

1x25

Nexans ref. 21025PHZOU000BD0

  • Conductor cross-section: 25 mm²
  • Nominal outer diameter: 8.5 mm
  • Approximate weight: 260 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.727 Ohm/km
  • Permissible current rating in open air: 171 A
  • Voltage Drop: 1.4 V/A.km

 

1x35

Nexans ref. 21035PHZOU000BD0

  • Conductor cross-section: 35 mm²
  • Nominal outer diameter: 9.5 mm
  • Approximate weight: 360 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.524 Ohm/km
  • Permissible current rating in open air: 210 A
  • Voltage Drop: 1.1 V/A.km

 

1x50

Nexans ref. 21050PHZOU000BD0

  • Conductor cross-section: 50 mm²
  • Nominal outer diameter: 11.0 mm
  • Approximate weight: 480 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.387 Ohm/km
  • Permissible current rating in open air: 262 A
  • Voltage Drop: 0.8 V/A.km

 

1x70

Nexans ref. 21070PHZOU000BD0

  • Conductor cross-section: 70 mm²
  • Nominal outer diameter: 13.0 mm
  • Approximate weight: 650 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.268 Ohm/km
  • Permissible current rating in open air: 325 A
  • Voltage Drop: 0.58 V/A.km

 

1x95

Nexans ref. 21095PHZOU000BD0

  • Conductor cross-section: 95 mm²
  • Nominal outer diameter: 15.0 mm
  • Approximate weight: 950 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.193 Ohm/km
  • Permissible current rating in open air: 387 A
  • Voltage Drop: 0.44 V/A.km

 

1x120

Nexans ref. 21120PHZOU000BD0

  • Conductor cross-section: 120 mm²
  • Nominal outer diameter: 16.0 mm
  • Approximate weight: 1200 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.153 Ohm/km
  • Permissible current rating in open air: 456 A
  • Voltage Drop: 0.37 V/A.km

 

1x150

Nexans ref. 21150PHZOU000BD0

  • Conductor cross-section: 150 mm²
  • Nominal outer diameter: 18.0 mm
  • Approximate weight: 1400 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.124 Ohm/km
  • Permissible current rating in open air: 518 A
  • Voltage Drop: 0.32 V/A.km

 

1x185

Nexans ref. 21185PHZOU000BD0

  • Conductor cross-section: 185 mm²
  • Nominal outer diameter: 20.0 mm
  • Approximate weight: 1800 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.099 Ohm/km
  • Permissible current rating in open air: 593 A
  • Voltage Drop: 0.27 V/A.km

 

1x240

Nexans ref. 21240PHZOU000BD0

  • Conductor cross-section: 240 mm²
  • Nominal outer diameter: 23.0 mm
  • Approximate weight: 2970 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.075 Ohm/km
  • Permissible current rating in open air: 700 A
  • Voltage Drop: 0.23 V/A.km

 

1x300

Nexans ref. 21300PHZOU000BD0

  • Conductor cross-section: 300 mm²
  • Nominal outer diameter: 26.0 mm
  • Approximate weight: 3600 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.06 Ohm/km
  • Permissible current rating in open air: 806 A
  • Voltage Drop: 0.2 V/A.km

 

1x400

Nexans ref. 21400PHZOU000BD0

  • Conductor cross-section: 400 mm²
  • Nominal outer diameter: 29.0 mm
  • Approximate weight: 4600 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.047 Ohm/km
  • Permissible current rating in open air: 962 A
  • Voltage Drop: 0.18 V/A.km

 

1x500

Nexans ref. 21500PHZOU000BD0

  • Conductor cross-section: 500 mm²
  • Nominal outer diameter: 33.0 mm
  • Approximate weight: 5970 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.037 Ohm/km
  • Permissible current rating in open air: 1100 A
  • Voltage Drop: 0.15 V/A.km

 

1x630

Nexans ref. 21630PHZOU000BD0

  • Conductor cross-section: 630 mm²
  • Nominal outer diameter: 36.0 mm
  • Approximate weight: 7350 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.028 Ohm/km
  • Permissible current rating in open air: 1227 A
  • Voltage Drop: 0.14 V/A.km

 

1x800

Nexans ref. 21800PHZOU000BD0

  • Conductor cross-section: 800 mm²
  • Nominal outer diameter: 39.0 mm
  • Approximate weight: 7600 kg/km
  • Max. DC resistance of the conductor at 20°C: 0.022 Ohm/km
  • Permissible current rating in open air: 1290 A
  • Voltage Drop: 0.13 V/A.km

 

Description

Description

Standards

  • Product
    BS 7211; EN 50525-3-41

Application:

Used in energy networks in refineries,mines,hotels,schools,tunnels,high constructions,hospitals,power plants, data processing centers,business centers where there is a risk of fire.

 

  1. Conductor

        Stranded bare copper class 2 to BS EN 60228

  1. Fire barrier 

        Mica Glass Tape

  1. Insulation 

        Cross Linked Halogen Free "XL-HFFR"

 

Installation

In conduit, insulated support, ducts...in coverd and dry place.

Packing

The packing will be in coils with 91.4 m.

 

Marking:

450/750 V   Cu/Mica/XL-FFR  no. of cores x cable size  H07Z-R   EN 50525-3.41 LPCB Made in Qatar

 

Permissible current and voltage drop are given

For conductor laid alone in insulating tube on a wall Temperature = 30°C.
Permanent operation If conditions are different, apply correction factors from  IEC 60364-5-52 standard or other equivalent national standard Voltage drop Calculated with cosj = 0,8

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor flexibility
Stranded class 2
Conductor material
Copper
Conductor shape
Circular stranded (RM)
Insulation
XL-HFFR
Halogen free
Yes

Dimensional characteristics

Dimensional characteristics

Number of cores
1
Length
- mm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Mechanical characteristics

Mechanical characteristics

Mechanical resistance to impacts
Low
Cable flexibility
Rigid

Usage characteristics

Usage characteristics

Flame retardant
IEC 60332-1-2
Operating temperature, range
-20 ... 60 °C
Short-circuit max. conductor temperature
250 °C
Smoke density
IEC 61034
Gases corrosivity
IEC 60754-2

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close